Product brochure
English | PDF | 1.3 MB
Download nowGamma radiation, emitted from a shielded source is attenuated as it passes through the vessel. This attenuation is measured by a highly sensitive detector, mounted at the opposite side of the vessel. As type of radiation and measuring geometry are constant the attenuation will only be affected by a change in level.
The continuous measurement of level uses a radiation field over the whole measuring range. If the level rises within the range of the radiation field, the attenuation becomes stronger and consequently the detector measures less radiation. In this manner, the level can be reliably monitored - irrespective of pressure, temperature, viscosity, color and all chemical properties.
There are different possibilities how a radiation field is formed. Either a rod detector or a rod source is used; sometimes it is most beneficial to use both in combination.
Learn more
1 2-wire systems with separate transmitters: 2-wire measuring system consisting of detector and transmitter, in which the transmitter
is housed in the control room.
2 Compact probe: detector with integrated transmitter, which is operated via HART or bus communication.
The TowerSENS with a maximum sensitive length of 8 m is an extremely efficient solution for long measuring ranges. The TowerSENS detector ensures high sensitivity and accuracy over the whole measuring range.
When compared to our comptetitors, our detectors with industry leading sensitivity achieve better accuracy with the same source, or can extend the useful life of aged and low activity sources. Depending on the application, the source activity can be reduced by up to 80%.
The longterm stability of a detector is extremely important for consistent high quality measurement performance and accuracy during the many years of operation. Longterm drifts of detector sensitivity can be caused by temperature changes and aging. If they go unnoticed and are not compensated, they can cause a considerable loss in production yields and product quality suffers. See how our detectors maintain industry leading longterm stability.
With this function, weld tests no longer cause sudden fluctuations in the measured value. When weld tests are detected, the measured value is frozen until the external radiation event ends. A digital output signals the detection of interfering radiation.
All of our level measurement detectors are equipped with XIP.
Does your product naturally emit radiation? No problem!
The Product Radiation Compensation (PRC) independently measures gamma from the product and removes its effect upon the measurement, for a reliable accurate level measurement.
Gas property fluctuations in large vessels can greatly impact the amount of gamma at the detector, and therefore impact the measured value, if Berthold's gas property compensation is not added. With GPC, a second detector monitors how much the gas properties are effecting gamma transmission. Based on this, the level detector compensates for changes in gas properties, providing a reliable level measurement.
DuoSeries LB 4700 | SENSseries LB 480 | LoopSeries LB 430 | |
---|---|---|---|
4-20mA | |||
HART |
DuoSeries LB 4700 | SENSseries LB 480 | LoopSeries LB 430 | |
---|---|---|---|
ATEX / IECEx | |||
Intrinsically safe signal output | |||
Intrinsically safe power supply | |||
US/Canada (FM / CSA) | (X) | ||
SIL 2/3 |
DuoSeries LB 4700 | SENSseries LB 480 | LoopSeries LB 430 | |
---|---|---|---|
CrystalSENS | |||
UniSENS | |||
TowerSENS | |||
SuperSENS |
DuoSeries LB 470 | SENSseries LB 480 | LoopSeries LB 430 | |
---|---|---|---|
Monitored current output | |||
X-Ray Interference Protection (XIP) | |||
Radiation Interference Discrimination (RID) | |||
Gas Property Compensation (GPC) | |||
Compensation of natural product radioactivity (PRC) | |||
Product Buildup Compensation (PBC) | |||
Speedstar (50 ms response time) | |||
Loop Powered | |||
Optional display module |
DuoSeries LB 470 | SENSseries LB 480 | LoopSeries LB 430 | |
---|---|---|---|
Separate transmitter | |||
HART communication | |||
AMS / PDM / FDT / DTM | |||
Ethernet |
Product brochure
English | PDF | 1.3 MB
Download nowWhitepaper
English | PDF | 1.8 MB
Download nowProduct brochure
English | PDF | 1.3 MB
Download nowWhitepaper
English | PDF | 1.8 MB
Download nowDo you need help selecting the continuous level measurement system that best fits your industry and application?
Contact our worldwide network of engineers and service technicians for expert advice and support from initial inquiry through installation and eventual source reclamation. We are here for you!